DATA LOGGER
DATA LOGGER
· VA600 >
VA600 Multi-function Data Logger
Introduction:
Multi-function data logger is a new instrument designed for the actual demand of various industrial site, which integrating display, processing, records, calibration, accumulate, alarm functions etc. It can be used to measure the voltage, low current (0-24mA), high current (0 ~ 600A), temperature (thermocouple), temperature (thermal resistance RTD), etc.

Features:
· Up to 16000 data record point
· USB port connect to PC to browse the recording data, and generation curve, export the file with TXT/excel format.
· Maximum/minimun display and alarm function
· Low power indication, Auto sleep and wake up function
· Online mode log more than 16000 point
· Receive various input signal as thermocouple, RTD, current and voltage etc.
· Long battery life: 3 year (measure and record each 1 hour)
· IP65 or IP40 housing
· Magnetic mounting
· Upper and lower alarms seting
· Mini USB port connector
· Power failure do not lost log data

Specifications:
· Temperature (internal NTC):
  -30~+60℃ ±1℃
· Humidity: 20~90%RH ±3%RH
· Voltage: DC 0~10V ±0.02V
    AC 0~600V ±1.0V
· Current: DC 0~24mA ±0.05mA
· Current (external clamp head):
  AC/DC 0~600A ±1~2.5%
· Temperature (external thermocouple):
  K J -200~1000℃ ±0.4%reading±1.2℃, include cold junction compensate
· Temperature (external RTD):
  PT100 -200~1000℃
  PT1000 -200~1000℃
  ±0.5%, ±0.5℃
 
VA600 Data Logger
Basic
Single way
Dual ways
Specification
 
VA600
VA601
VA602
Parameter
Range
Accuary
Internal sensor
N
internal NTC
-30~60℃
±1℃
NH
 
 
internal NTC
internal RH%
-30~60℃
20~90% (0~100%)
±1℃,±3%RH
Voltage
V1
 
○○
V DC
0~10V
±0.02V
V2
 
○○
V AC
0~380V
1.0V
Current
A1
 
○○
mA DC
0~24mA (4~20mA)
±0.05mA
A2
 
○○
A AC
0~600A (clamp Adapter)
±2.5%
Thermocouple
TK
 
○○
TC-K TYPE
-200~1000℃
±1.2℃
TJ
 
○○
TC-J TYPE
-200~1000℃
±1.2℃
PTC
R1
 
○○
PT100
-200~1000℃
±0.5%, ±0.5℃
R2
 
○○
PT1000
-200~1000℃
±0.5%, ±0.5℃
OptionInclude internal NTC temperature measurement function
VA600 – XX
XX Measurement parameters:
N: Internal temperature measurement
NH: Internal temperature+Humidity measurement
VA600 Basic type
For example: VA600-N internal NTC temperature
N
NH
VA601 – XX
XX-CH1 measurement parameters:
V1: DCV 0~10V
V2: ACV 0~380V
A1: DCmA 0~24mA
A2: ACA 0~600A
TK: TC-K TYPE
TJ: TC-J TYPE
R1: PT100
R2: PT1000
VA601 External single way
(include internal NTC temperature measurement)
For example: VA601-V1 external DCV 0~10V
TK
TJ
V1
V2
A1
A2
R1
R2
VA602-XX-XX
XX-CH1 measurement parameters:
V1: DCV 0~10V
V2: ACV 0~380V
A1: DCmA 0~24mA
A2: ACA 0~600A
TK: TC-K TYPE
TJ: TC-J TYPE
R1: PT100
R2: PT1000
XX-CH2 measurement parameters:
V1: DCV 0~10V
V2: ACV 0~380V
A1: DCmA 0~24mA
A2: ACA 0~600A
TK: TC-K TYPE
TJ: TC-J TYPE
R1: PT100
R2: PT1000
VA602 External dual ways
(include internal temperature measurement)
For example: VA602-V1-R1
external 1 DCV 0~10V
external 2 PT100

V1-V2 / V2-R2
V1-A1 / A1-A2
V1-A2 / A1-R1
V1-R1 / A2-R1
V1-R2 / A1-R2
V2-A1 / A2-R1
V2-A2 / R1-R2
V2-R1
TK-TJ
TK-TK
TJ-TJ
V1-TK / A1-TJ
V2-TK / A2-TJ
V1-TJ / R1-TK
V2-TJ / R2-TK
A1-TK / R1-TJ
A2-TK / R2-TJ
Copyright 2005 SHANGHAI YIHUA V&A INSTRUMENT CO.,LTD. All Rights Reserved